180.
Fill gravity flow cup (max. 20 mm below upper edge), close with the lid
[2-11] and insert anti-drip device [2-12].
181.
Screw connection nipple [2-13] (not included in delivery) onto the air
inlet.
182.
Connect compressed air hose [2-14].
7.1. Adjustment of the Spray Gun Inlet Pressure
• Pull the trigger fully and adjust the spray gun inlet pressure (see chap-
ter 2) following the instructions of one of the followig sections ([3-1],
[3-2], [3-3], [3-4] bis [3-5]), then release the trigger.
• With [3-3], [3-4] and [3-5], the air micrometer [1-13] must be fully
opened/in vertical position.
• If the required spray gun inlet pressure is not reached, the pressure
at the compressed air circuit has to be increased; too high pressure
results in too high trigger forces.
[3-1] Spray gun with digital pressure display (accurate method).
[3-2] SATA adam 2 (accessory / accurate method).
[3-3] Separate analogue gauge with regulation device (accessory).
[3-4] Separate analogue gauge without regulation device (accesso-
ry).
[3-5] Pressure regulation at the compressed air circuit (least
accurate method):
rule of thumb: pressure at the pressure reducer must be set 0.6
bar higher than the recommended spray gun inlet pressure per
every 10 m of air hose (inner width 9 mm).
7.2. Adjustment of the Material Flow
und [4-4] - material flow control fully opened
With the material flow control fully opened, the wear of the fluid tip and
paint needle is reduced to a minimum. Please select the correct nozzle
size depending on the material to be applied and the required applica-
tion speed.
Information!
Information!
[4-1], [4-2], [4-3]