Protective Devices Tripping - akkuteam SL50 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Protective
Warning triangle flashes red every 1.5 seconds
devices tripping
Cause:
Rectification:
Warning triangle flashes red twice in succession every 1.5 seconds
Cause:
Rectification:
Warning triangle flashes red three times in a row every 1.5 seconds
Cause:
Rectification:
Warning triangle flashes red four times in a row every 1.5 seconds
Cause:
Rectification:
Warning triangle flashes red six times in a row every 1.5 seconds
Cause:
Rectification:
Warning triangle flashes red seven times in a row every 1.5 seconds
Cause:
Rectification:
CAUTION! Inadequate PE conductor connections can
cause serious injury and damage. The housing screws provide
a suitable PE conductor connection for earthing (grounding)
the housing and must NOT be replaced by any other screws
that do not provide a reliable PE conductor connection.
Battery disconnected for less than 30 seconds
Make sure that the loading clamps are secure and secure.
Battery disconnected for more than 30 seconds
Make sure that the loading clamps are secure and secure.
Over temperature protection
Check whether the cooling fins of the device are not
covered or dirty. Reduce the ambient temperature to 30°C.
Short circuit protection
Check charging cables, contacts and battery poles.
Battery fault
Check defective battery for cell short-circuit or sulfation.
Too much parallel load connected
Check the number of connected batteries. Connect only
one battery at a time.
54