Interrupti ng charging
Stopping
charging
Restarti ng
charging
Troubleshooti ng
The charger analyses the batt ery again aft er the charging phase. Post analysis can detect
batt eries with a short circuit in individual cells. This cannot be detected in the pre analysis. If
the batt ery voltage drops below 12 V within 2 min, the charger will go into error mode and the
red warning triangle will start to fl ash. The charging sequence will be stopped.

Safety

NOTE! Risk of damage to connecti on sockets and plugs. Do
not disconnect or unplug the charging cable while charging.
1. Press the Stop/Start butt on to stop charging.
2. Charging stopped – operati ng indicator fl ashes.
3. Press the Stop/Start butt on to conti nue charging.
WARNING! An electric shock can be fatal. Before opening
the device
– Unplug the device from the mains,
– Disconnect batt ery connecti on,
– Put up an easy-to-understand warning sign to stop
anybody inadvertently switching it back on again,
– Using a suitable measuring instrument, check to make
sure that electrically charged components (e.g. capaci-
tors) have discharged.