Technical Data; Mechanical Data - akkuteam SL50 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical data

Electrical data
Mains voltage
input
Mains frequency
Mains current
Mains fuse protection
Efficiency
Effective power
Power consumption (standby)
Protection class
Maximum permitted mains
impedance at the interface
(PCC) to the public grid
EMV emission class
Electrical data
Nominal output voltage
output
Output voltage range
Output current
Battery return current
Mechanical
Cooling
data
Dimensions H × W × D
Weight (without cable)
Environmental
Operating temperature
conditions
Storage temperature
Degree of protection,
horizontal position
100 – 240 V AC
50 / 60 Hz
max. 7.1 A
4 A
max. 94 %
max. 800 W
1.7 W
I
none
EN55011
12 V DC
10.5 – 16 V DC
50 A bei 14.8 V DC
< 1 mA
Convection
280 × 175 × 85 mm
3.8 kg
-20°C to +60°C
-35°C to +70°C
IP5K3
56
EN

Publicité

Table des Matières
loading

Table des Matières