Fig. 6.1a
TECHNICAL INFORMATION
FOR THE INSTALLER
Before installing the cooktop, remove the
protective film.
This cooktop can be built into a working
surface 20 to 40 mm thick and 600 mm
deep.
In order to install the cooker top into the
kitchen fixture, a hole with the dimensions
shown in figs. 6.1a - 6.1b has to be made,
keeping in consideration the following:
– within the fixture, between the bottom side
of the cooker top and the upper surface
of any other appliance or internal shelf
there must be a clearance of at least 30
mm;
– the cooker top must be kept no less than
100 mm away from any side wall;
– the cooker top must be kept at a distance
of no less than 50 mm from the rear wall.
– there must be a distance of at least 650
mm between the hob and any wall
cupboard or extractor hood positioned
immediately above (see fig. 6.2)
20
GAS COOKING HOBS
– the coatings of the walls of the unit or
appliances near the cooktop must be
heat resistant ("Y" protection against
heating in compliance with standards
EN 60335-2-6).
Do not instal the appliance near
inflammable materials (eg. curtains).
Fig. 6.2
Fig. 6.1b