Fleischmann 741272 Instructions De Service page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
28 speed steps. Probably the running of the loco has been set to 14 steps. Simply
re-set the equipment to 28 steps, or re-program the Sound decoder to
14 steps (see CV29 in chapter 5).
2. The loco sound is not clear:
Run the loco in pure DCC- or Motorola*-operation.
3. The loco does not respond to Motorola* commands:
If the decoder is set to handle the long DCC-address, then you must change the
setting to use the short address (CV29, bit5 = 0).
5. LIST OF THE IMPORTANT CV's
CV Name
Basic Description
Value
1 Loco address
accor- Defines the digital Address for DCC (3)
ding
to the dress of the loco decoder
loco
2 Start-up voltage accor- This CV sets the motor voltage of speed
ding
to the the motor characteristic table
loco
3 Acceleration
accor- Inertia values when accelerating
inertia
ding
to the
loco
4 Braking inertia
accor- Inertia values when braking
ding
to the
loco
5
Maximum
accor-
voltage
ding
to the
loco
10
and Motorola* (78/72/24/60) 1-Byte ad-
level 1, if not set by CV 29 Bit 4 as in
This CV sets the running voltage of the
highest speed level. Possible maximum
is 252. See also CV2.
6 Middle
accor- Running voltage setting for the middle
voltage
ding
area speed steps.
to the By using this CV it is possible to set a
loco
non-linear control characteristic.
8 Manufacturer
145
NMRA identification number for producer
Identification
Zimo. By programming this CV with
the value 8 will re-set to the factory
setting. Warning: the control unit
may indicate an error.
13 Analogmode
01
(00 - no function in analogmode)
F1 through F8
01 - function F1 02 - function F2
04 - function F3 08 - function F4
16 - function F5 32 - function F6
64 - function F7 128- function F8
Attention:
While activating multiple functions
(value adding) for the CV's in analogmo
de, the execution is simultaneous.
14 Analogmode
0
01 - frontlight ahead
F9 through F12,
02 - frontlight rear
and frontlight
04 - function F9
16 - function F11 32 - function F12
64 - analogmode without delay
possible (CV3, CV4)
128- analogmode controlled
17 Long
192
Upper section of long addresses.
Addresses
Effective on DCC with CV29 Bit 5 = 1.
(upper section)
When programming a long address with
the TWIN-CENTER or the PROFI-
BOSS, CV's 17, 18 and 29 are automati
cally set. While programming with the
multiMAUS and multiMAUS
CV's 17 and 18 are set.
08 - function F10
, only
PRO