Options
5
5.1 Visual clogging indicator
To make the filter (HighTech design) easier to maintain we recommend
upgrading it with the easy-read visual clogging indicator type "UED".
Type of indication
Weight
Pressure setting / indication range
Permitted operating pressure
Permitted temperature range
Thread
Max. torque value
Order example
HYDAC Part no.:
If your filter module is fitted with this kind of vacuum gauge, please cut the top off the seal
plug on the vacuum gauge once the filter module has been finally installed on your machine.
The indicator must always be installed with the seal plug uppermost.
The clogging indicator must always be glued into the housing using Loctite 2701.
36
Visual-analogue, scale indication (silicone filled)
100 g
-1 bar to 0 bar
-0.7 to 0 bar – continuous
-20°C to +90°C
G 1/8
–
VMF 1 UED.0
1303275
Cut the top
off the seal plug
before commissioning
the vacuum gauge.