9.3. Adjustment of the 1078-2
danger
risk of electric shock.
• Shut down the electrical power source of all the con-
ductors and isolate it to avoid modifying the param-
eters of the 1078-2 before inserting the configuration
module type 1077-2 on the timer 1078-2.
To change the parameters of the 1078-2, install a configu-
ration module type 1077-2 on the timer 1078-2.
Check that both red LEDs are OFF.
Loosen the screw from the 1078-2.
Remove the cover.
Install the 1077-2 with its seal onto the 1078-2, in any
position. See Fig. 6, page 22.
Insert the screw supplied with the 1077-2.
Tighten the screw at a torque rating between 0,5 and
0,8 Nm.
English
32
9.3.2.
Display elements of the 1077-2
Time units for the displayed time:
hours, minutes and/or seconds
h m s
- At the Read level:
199:99
Shows that the output is
closed
- At the Settings level:
Shows that the ON/OFF
contact is normally open
- At the Read level:
Shows that the output
is open
- At the Settings level:
Shows that the ON/OFF
contact is normally closed
Fig. 13: Display of the 1077-2
9.3.3.
operating levels
The configuration module has two operating levels: The
Read level and the Settings level.
English
34
Setting for the reset
input
Shows a time. If "--:--"
is displayed the set
cycle is completed.
Shows that the device
is beeing adjusted
Shows the operating
mode
9.3.1.
Adjustment keys of the 1077-2
To access the Settings level.
+
• From the Read level to go to the next time.
• From the Settings level to go to the next
function.
• To validate the setting of each function.
• At the end of the adjustment, to transfer the
new settings to the timer.
At the Settings level:
• To change the flashing numerical value.
• To go to the next choice of a function.
Fig. 12: Adjustment of the 1077-2
• The Read level allows for reading the different times that
have been set and for following their count down.
• The Settings level allows for setting the operating mode,
the reset type and the times (units and values).
9.3.4.
navigating within the Read level
99:00
99:01
10:10
Fig. 14: Navigation at the Read level
English
When the device is energized
or when the Settings level
is left, the display shows
the first running time (which
depends on the set operating
mode).The count-down of
that time starts.
The next screens show the
other set times.The number
of times depends on the set
operating mode.