To allow the bow thruster or stern thruster to be distinguished
on the CAN bus, these must be configured appropriately .
Bow thruster
The configuration as supplied is for application as a bow thruster.
Stern thruster
Configure a stern thruster by cutting through the red wire as indica-
ted in the drawing.
• Reinstall the cover and tighten the glands.
Main power fuse 2
In the connection unit, there
is a main power fuse on the
controller.
This fuse protects the con-
troller and motor against
short
circuit/overloading
and it must remain present
under all circumstances .
When replacing the fuse, the replacement must be of the
same rating .
5 .6
Connecting control voltage cables
• Mount the control panel
at the helm position.
There must be 150 mm
of free space behind the
panel.
28
020806.07
n
ote
Red
n
ote
- BPPJA
- BPPPA
• Connect the panel as shown in the diagram.
See diagrams on page
ed.
• Connect the hub to a 12-Volt power supply.
Control panel
Terminator
Connection cable
Hub
48 V
+
12 V
Control voltage fuse
The hub should also be connected to 12 Volts
n
ote
in the case of a 48-Volt bow thruster .
7
12 V
+
3
7
12 V
+
3
The CAN bus is a chain to which the bow thruster and the panels are
connected.
At one end of the chain, the power supply (3) must be connected
and the terminator (7) must be connected at the other end!
vetus® Installation instructions BOW PRO Series Thrusters: BOWA0651 and BOWA0764
143
if several panels have to be connect-
Connection box thruster
Connection cable
CAN-bus supply
M
M
12 V
+
3
n
ote
M