and projectiles temperature less than 60 ° C.
5.
Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
6.
Do not place any object on the lens.
7.
Handling at least allow the device to cool for 20 minutes.
8.
Do not replace the non-original parts.
. PACKAGE
3
BEAM-2RX packed with carton box, the fly-case for two BEAM-2RX is available in option.
3.1
TRANSPORT PROTECT LOCK
In order to protect the light, there is a protect lock.
During the transport, the lock will closed keeping the item in safety state.
3.2
ABOUT PACK STAGE
1. Before packed, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X, Y axis protect lock closed.
3. After packed by plastic bag, high-lift the fixture with two handles besides the product. put the product into
the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
6. When packed with carton box, equipment should be put into the foam first, and then set into a carton,
pay attention to the vertical position.
3.3
UNPACKING
1. Open the fly-case, high-lift the product by two handles beside the bottom base and move it out.
2. Before power on, make sure you have opened the X, Y axis lock!
4-
INSTALL STANDARD
4.1
INSTALL LOCK
The BEAM-2RX can be placed on the stage, or mounted in an arbitrary direction of the truss.
Two fast locks system could fix the item easily.
4.2
EQUIPMENT FIXED
1. Before installation must verify the fast lock is keep in good state, and can withstand at least 10 times the
weight of product. Verify that the building can withstand at least 10 times of the total weight of the product
and accessory equipments.
2. Fix the hang fixture into the hole, which located on the base of the light.
Seize handle of fasteners, clockwise rotate 1/4 turn and lock. Installed other one fastener
in the same method.
3. Using the safety cable which can withstand 10 times the weight of the equipment.
4. Make sure the X, Y protect locks are opened, Verify that within 3 meters there is no combustibles.
WARNING
Fixture must use two fixing devices, and make sure the fixing device have locked! And only fully clockwise
rotate 90 ° can lock the hang fixture! Do remember plus a safety rope, and do not connect the safety rope
to plastic handle. It should be connect to the hole on the base!