LED Display
The SDC 2300 is equipped with an LED display
which provides a visual indication of target size
and proximity. When detecting, the first LED
is always illuminated. Small or deep targets
may only cause the first two to three LEDs to
illuminate. Very large or shallow targets may
cause all LEDs to illuminate.
There is also a single low battery alarm LED,
which will flash when the batteries are nearly
depleted.
Weak target response
e.g. Small or deep targets
Strong target response
e.g. Large or shallow targets
Low battery alarm
LED Display
Battery Status
The battery status can be checked at anytime.
To check your battery level, follow the steps
below:
1. Press and hold the Noise Cancel button.
2. Press and release the Threshold button.
The Noise Cancel button can now be
released.
3. An indication of battery charge will be
displayed by the LEDs for approximately
three seconds.
NOTE:
Fully charged rechargeable batteries will only
indicate half charge:
Fully charged
rechargeable 1.2V
7
Fresh Alkaline 1.5V