7. BUG FIXING

PROBLEM
The machine doesn't work�
The dehumidification func-
tion cannot be started�
No wind
The device is louder than
usual
E1 Code
POSSIBLE CAUSES
The power supply is not
connected correctly�
The water tank is full�
The room temperature is
below 5º C or above 35º C
The filter is blocked�
The air inlet or outlet is
blocked�
The filter is blocked�
The device is tilted�
The filter is blocked�
Short circuit or interruption of
the coil sensor
57
PROPOSED SOLUTIONS
Connect power supply cor-
rectly or check for damage
Empty water tank
Regulate room temperature
Clean the filter according to
the instructions
Remove the obstruction from
the air inlet or outlet�
Clean the filter according to
the instructions
Transport the device onto a
flat, level surface�
Clean the filter according to
the instructions
Check if the cable is loose
have the coil sensor replaced
by a certified technician�