4. USAGE

EN
1. Water pump (only for SECCO 4000)
The unit can be operated without a water tank by connecting it to the direct drain
(fig� 1, no� 3)� To do this, connect a plastic hose (Ø 10 mm) to the valve provided
above the water tank� Make sure that the hose is correctly installed and that there
is no kink� Now the pump can be activated�
2. Timer
Off Timer: When the unit is in operation, the timer button can be pressed to cont-
rol when the unit should be turned off�
On timer: When the unit is turned off, the timer button can be used to control when
the unit should start operation�
The time can be set between 1-24 hours�
If the timer is switched off, the display shows the humidity again after 5 seconds�
3. Modus
With the mode button the device can be set between 3 modes:
A. Ventilation: The unit circulates air without dehumidifying in two different sta-
ges� The fan runs in each mode to ensure optimal air circulation�
B. Dehumidify: The unit dehumidifies according to the set guide value:
30-90 % / AU: Comfort / CO: Continuous (As soon as the humidity drops to the set
humidity level, the compressor switches off, the fan continues to run at a low level
for good air distribution�)
C. Clothes drying: The unit dehumidifies at a high level regardless of room humi-
dity�
NOTE: DO NOT ALLOW THE DEVICE TO BE USED BEFORE
THE FIRST COMMISSIONING AT LEAST 12 HOURS.
52