ENTRETIEN
17.Inspect the lower cyclone chamber flaps and
ensure they open and close completely.
Remove any excessive dust buildup on the
flaps.
18.Allow the lower cyclone compartment / dust
filter compartment / Perma−Filter compartment
to completely dry.
19.Turn on the machine, lower the hopper, and turn
off the machine.
20.With the help of an assistant, reinstall the lower
cyclone chamber into the hopper. Ensure no
hoses or harness leads are pinched between
the bottom of the lower cyclone chamber and
the top of the hopper.
21.Reinstall the four brackets to secure the lower
cyclone chamber to the hopper.
22.Secure the main wire harness to the lower
cyclone chamber and reconnect the main wire
harness to the lower cyclone chamber harness.
NOTE: Be sure the main wire harness is routed to
the outside of the bracket. The upper cyclone
chamber will not seat properly if harness is routed to
the inside.
62
23.Reinstall the upper cyclone assembly, dust filter,
and HEPA filter assembly in reverse order of
disassembly.
FILTRE PERMA DU CYCLONE
Le cas échéant, nettoyez la poussière lourde ou
'
humide et l
excès de débris du filtre Perma du
'
cyclone. Vérifiez l
endommagement du filtre Perma
du cyclone toutes les 100 heures de service.
S20 Gas/LP 9007264 (5-2018)