Danger of short circuits and
damage to unit! Water will
penetrate if the power cable is
CAUTION
incorrectly fed into the
terminal box or if the cable
grommet [22] is not fitted
correctly.
 Pierce cable grommet with a
nozzle pin such that it tightly
clasps the power cable.
 Guide power cable correctly
into terminal box through
cable grommet.
 Guide power cable into terminal box
through cable grommet.
 Connect power cable to terminal block [20]
according to wiring diagram. For wiring
diagrams, see chapter 14 at the end of
these instructions or the terminal box
cover.
 Put the terminal block cover on and screw
it into place.
 Fit service switch on the roof, near to the
unit.
 Fit on/off switch.
 Fit speed controller if necessary.
 Fit reversing switch to air flow direction
reverser if necessary.
8.3 Start-up
 Ensure that the unit is correctly connected
and that the air can flow unhindered.
 Check that the technical data has been
adhered to, see rating plate S2.
 Switch on unit. The fan must run quietly.
 Switch off unit.
9. Maintenance
EZD.../DZD... units require no maintenance.
14
If maintenance work is required, please
observe the following:
Danger to life from electric
shock
 Before undertaking cleaning
DANGER
work, completely disconnect
unit from the power supply or
switch the service switch to
the "off" position and secure
against being switched back
on.
 Position a warning notice to
avoid the unit being
accidentally switched back on.
Danger of injury from rotating
impeller after switching off!
 Switch service switch to off
DANGER
position before removing the
roof cowl.
 Wait until the impeller is
stationary.
Risk of cuts from metal
housing plates with sharp
edges.
CAUTION
 Wear protective gloves.
10. Fault rectification
● Call on the services of a trained
electrician any time there is a fault.
● Repairs should only be carried out by a
trained electrician.
Danger to life from electric
shock when working on
electrical equipment!
DANGER
 Before removing the terminal
box cover or the roof cowl,
switch the service switch to
the "off" position and secure
against being switched back
on.
 Position a warning notice to
avoid the unit being
accidentally switched back on.