The ThunderION can be powered by a 24 V power supply which is already available on the
machine (and which complies with the requirements above), or a power unit provided by SIMCO
(Nederland) B.V.
The power supplies recommended by SIMCO (Nederland) B.V.:
4510001010
Separate 100-240 V AC to 24 V DC power supply for 1 ThunderION
4510001400
Control module for max. 4 ThunderIONs
Attention! ThunderIONs combined with the Control Module do not conform to
UL standards
7519020430
100–240 V AC to 24 V DC DIN rail power supply for 2 ThunderIONs.
Maximum total length 6 m (length of bar 1 + length of bar 2)
7519020425
100–240 V AC to 24 V DC DIN rail power supply for 2 ThunderIONs.
Attention! ThunderIONs combined with this power supply do not conform to UL
standards
7519020435
100–240 V AC to 24 V DC DIN rail power supply for 6 ThunderIONs.
Attention! ThunderIONs combined with this power supply do not conform to UL
standards
For more information on these power supplies, please contact SIMCO (Nederland) B.V. or your
regional agent.

4. Installation

4.1. Prior check

- Check that the bar is undamaged and that you have received the correct model.
- Check that the data on the packing slip corresponds to the data shown on the received
product.
If you have any problems and/or if in doubt:
please contact SIMCO (Nederland) B.V. or your regional agent.

4.2. General

Fit the anti-static bar right
In places where the material is neutralized, it must have a layer of air under it.
The correct distance from the anti-static bar to the material should be established by experiment
(see technical specifications).
The emitters of the anti-static bar must not be covered.
Warning:
When carrying out work on the equipment, always disconnect the power supply to the
-
equipment.
Work on the equipment must be carried out by a skilled and qualified electrical
-
engineer.
Equipment must be earthed to ensure that it works properly and safely.
-
-
Only connect the specified voltages to the circuits.
Only use the supplied fasteners.
-
ThunderION_UM_9752160010_NL_D_GB_F_V2_2
before
the location where static electricity is causing trouble.
GB
31