Dismantling the module
Unlatch both locking hooks by using a screwdriver on the end dismantling-grooves.
Remove the block part / module sideways.
Other possible uses of the connecting module, - right-hand -
• As a separation module for special applications when building up several pressure levels in a single
block.
• Additional supply lines for larger valve blocks
Mounting the valve block
Standard rails
Figure: Mounting the valve block
INSTALLATION, INITIALISATION AND SERVICE
INSTALLATION
Hang the valve block onto the upper groove of
the standard rail.
Latch the lower clamp into the standard rail.
Firmly tighten the screws on the clamp.
DISMOUNTING
Loosen the clamping screws (by about 4
revolutions).
Remove the block upwards from the standard
rail.