Télécharger Imprimer la page

Soehnle Style Sense Multi 200 Mode D'emploi page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 8
A. Operating elements
EN
1. Switch on / Confirm (SET)
2. Plus ( )
3. Minus ( )
Sensor Touch:
Touch keys only slightly!
B. Preparation
1. Insert batteries.
Note:
Place the body analysis scale immediately on
solid and even surface (as long as „0,0" is
still displayed) and wait until the scale turns
off automatically.
Only then begin with data input. Note, it
might occur that the initial scale weight is
being added erroneously to the personal
weight process.
The same may happen during regular operati-
on, if scale is held in the hand prior to the
weight process.
2. Place scale on solid and even surface (not
carpet). This applies for all measurements.
3. Cleaning and Care: use only a lightly damp
cloth for cleaning. Do not use solvents or
abrasives. Never submerge scale in water.
4. A country-specific option, to switch from kg/
cm to lb/in or st/in, is available on the back of
the scale by pushing key.
Attention! Slipping hazard
in case of wet surface.
C. Data input
1. Push SET key.
2. Use
/
keys to select memory slot and con-
firm (SET).
3. Then use
/
confirm.
4. Set target weight and confirm (Press SET key
3 sec.).
5. Place the body analysis scale immediately on
the floor, wait until screen displays „0,0" and
then step on the scale.
The initial measurement is indispensable and
serves to store data for later automatic recog-
nition. If no user steps on the scale, data
input must be repeated.
4
keys to enter body height and
The first body analysis is performed after a
user steps on the scale.
This scale is equipped with a timeout mode.
It will automatically turn off after approx. 40
seconds, if no keys are pressed.
Data must be entered again after battery
change.
D. Body analysis
1. Place scale on solid and even surface and
wait until scale switches off automatically.
Step on scale. Please stand still.
2. Determined body weight is displayed.
Automatic user recognition follows.
3. If the determined values cannot be clearly
allocated to one user, the possible memory
slots will be displayed.
If the determined weight can be allocated to
more than 2 users, other possible memory
slots will be displayed after 3 seconds.
Use the
/
keys ( = left,
firm the memory slot displayed there.
4. The determined body weight, BMI (Body Mass
Index) and the difference to the target weight
is displayed.
The scale turns off auto matically.
Classification of body weight according to BMI
(Source: World Health Organisation, 2016)
BMI (kg/m²)
classification
< 18.5
Underweight
18.5 - 24.9
Normal weight
25.0 - 29.9
Pre-obesity
30.0 - 34.9
Obesity level I
35.0 - 39.9
Obesity level II
> 40.0
Obesity level III
E. Notifications
1. Replace batteries
2. Overload: max. 180 kg
F. Technical data
Max. 180 kg / 100 g
Max. 396 lb / 0.2 lb
Max. 28 st / 0.2 lb
Batteriy requirement: 3 x 1,5 V AAA