Operation

17.4.5 Hybrid mode

The urinal controller allows the incorporation of a water-saving / hybrid mode by pushing a
key.
When the hybrid mode is activated, the urinal flushes only at fixed intervals.
The interval flushes are carried out only if use is detected within the interval.
If use is detected at the time of a planned flush, the flush is carried out only after the use has ta-
ken place.
Water saving / hybrid mode activation and deactivation
1.
Push the AUTO key for 10 seconds.
The LED lights up once after 10 seconds.
2.
Release the AUTO key..
Hybrid mode activated = LED lights up for 2 seconds.
Hybrid mode deactivated = LED lights up twice