Technical description
Spare part
16.2 General functional description
Flushing is triggered when the sensor detects a movement within the ceramic bowl. When the
urinal is used, a movement is created by fluid flowing over the ceramic surface.
The sensor is located behind the ceramic, above the retained water of the siphon. For this,
comply with the sensor positions in the separate installation instructions.
The ProDetect 2 is available as a mains model with an electrical connection, or as a battery mo-
del.
S. 54
Designation
HF Sensor
Solenoid valve
Backflow preventer
(insert into inlet spigot)
Sieve seal
(insert into hosing)
Item number
91906000
91906700
91906300
91906200