6.5 MASSAGE program table

Prog.
Reasonable areas of application
No.
Indications
1
Muscle strain relief
2
Relaxing massage
3
Invigorating massage
4
Tapping massage
5
Tapping and jet massage
6
Vibrating massage
7
Warm up massage 1
8
Warm up massage 2
9
Pressure massage
10
Kneading and pressure massage
Electrodes must be placed so that they surround the muscle segments in questi-
on. For optimal effect, electrode distance must not be greater than approx. 15 cm.
The electrodes should not be applied to the anterior wall of the thorax, i.e. never
massage the left or right large pectoral muscle.

7. Application

7.1 Advice on application

• If the machine is not used within 2 minutes, it switches off automatically (au-
tomatic switch-off function). When the unit is switched on again, the LCD
screen displays the menu selection and the most recently used menu flashes.
• If an admissible key is pressed, there is one short beep. If an inadmissible
key is pressed, there are two short beeps.
• You can pause the stimulation at any time by briefly pressing the ON/OFF
button
. To continue the stimulation, briefly press the ON/OFF button
again and set the desired impulse intensity again.
7.2 Procedure for programs TENS 1–7, EMS 1–27 and
MASSAGE 1–10 (quick start)
• Select a suitable program from the program tables (p. 23–27).
• Place the electrodes on the desired area for treatment (for positioning sug-
gestions see electrode positions, p. 2) and connect them to the device.
Selecting a program
• Press the ON/OFF button
Phase
Running time
• Using the M button, navigate through the menus
( minutes)
1
20
1
25
• Using the UP/DOWN buttons, select the desired program and
1
20
1
15
1
15
1
20
If you wish to return to the previous selection menu, press the M
1
20
button. By holding down the E button, you can skip individual set-
1
10
ting steps and start directly with the stimulation treatment.
1
20
Setting the impulse intensity
1
20
• Using the INTENSITY SETTING buttons, select the desired
• If the program is in a pause phase, the intensity cannot be increased.
• If you wish to end the stimulation treatment early, press the ON/OFF button

7.3 Setting individual parameters

7.3.1 Setting the treatment time
(TENS programs 8-10 and EMS programs 28-30 only)
Using the UP/DOWN buttons, select the desired treatment
time. You can set a treatment time from 5 minutes to 100 minutes
(Fig. 4, Example treatment time of 20 min.). Confirm your
selection with the E button. The stimulation treatment begins and
the operation status display starts to flash alternately (Fig. 5).
25
to switch on the device.
/
(Fig. 1, Example TENS display) and
confirm your selection with the E button.
confirm your selection with the E button (Fig. 2, Example TENS
program 03).
General information
At the start of stimulation treatment, the impulse intensity of
is set to 00 as default. No impulses are sent to the electrodes yet.
impulse intensity. The impulse intensity display is adjusted
accordingly (Fig. 3). The impulse intensity of
can be set individually.
/
Fig. 1
Fig. 2
and
and
Fig. 3
.
Fig. 4
Fig. 5