Operating Instructions SATA Automatic Gun
EN
If cleaning work is performed while the gun is still connected to the com-
pressed air circuit and material supply, components can unexpectedly
work loose and material can leak.
→ Disconnect the automatic gun from the compressed air circuit and the
material supply before all kinds of cleaning work.
Attention!
The use of aggressive cleaning agents can damage the automatic gun.
→ Do not use aggressive cleaning agents.
Only use suitable cleaning solutions for cleaning.
→ Use a neutral cleaning solution with a pH of 6–8.
→ Do not use acids, caustic solutions, bases, paint strippers, unsuitable
regenerates or other aggressive cleaning agents.
There is a risk of corrosion if the automatic gun is submerged in the
cleaning solution. → Do not submerge the automatic gun in cleaning
solution.
Incorrect cleaning tools can damage the holes and impair the spray fan
pattern.
→ Only use the SATA cleaning brushes.
→ Never use ultrasonic cleaners.

12. Malfunctions

The following table describes malfunctions together with their causes and
corrective action.
If it is not possible to remedy a malfunction with the described corrective
action, send the automatic gun to the SATA customer service department.
(Address see chapter 13).