13. Malfunctions
The following table describes malfunctions, their causes and correspond-
ing remedies.
If it is not possible to remedy the malfunctions with the described correc-
tive action, send the pressurized cup spray gun to the SATA customer
service department. (For address see chapter 14).
Malfunction
Material leaks from the
material needle seal
No material flow
Atomization not fine
enough
No material at the noz-
zle or not enough
14. After Sale Service
For accessories, spare parts and technical support, please contact your
local SATA dealer.
Operating Instructions SATA HRS
Cause
Material needle seal
defective.
No pressure for the
pressurized cup.
Not enough intake
pressure.
Material too viscous.
Wand diameter too
small.
Impurities in the wand. Clean the wand (see
Corrective Action
Replace the material
needle seal [3-6] (see
chapter 11.3)
Connect to the com-
pressed air circuit.
Remove the check
valve [1-18], clean and
replace if necessary
(see chapter 12.3).
Remove the inlet valve
[3-9], clean and re-
place if necessary (see
chapter 11.4 and chap-
ter 12.4).
Remove the quick cou-
pling [2-4], clean and
replace if necessary
(see chapter 11.1).
Increase the intake
pressure.
Use a wand with a
larger diameter.
chapter 12.2).