3.1 Fire Prevention Measures
There is a certain element of danger every time you use
your fi replace. The following instructions must therefore be
followed:
•
The minimum safety distances when installing and using
the fi replace are given in fi g. 2 in the installation manuals
for the products.
•
Ensure that furniture and other combustible materials are
not too close to the fi replace. Combustible materials must
not be placed within 1,000 mm of the fi replace opening.
•
Allow the fi re to burn out. Never extinguish the fl ames with
water.
•
The fi replace becomes hot when lit and may cause burns
if touched.
•
Only remove ash when the fi replace is cold. Ash can
contain hot embers and should therefore be placed in a
non-fl ammable container.
•
Ash should be placed outdoors or be emptied in a place
where it will not present a potential fi re hazard
In the event of fi re in the chimney.
•
Close all doors and valves.
•
Keep the fi rebox door closed.
•
Check the loft and the basement for smoke.
•
Call the fi re brigade.
•
Before a fi replace can be used after a fi re or an attempted
fi re, the fi replace and the chimney must be inspected and
found to be in order by competent personnel.
3.2 Floor
Foundation
You must make sure that the foundation is suitable for the
fi replace. See "2.0 Technical Data" for specifi ed weight.
We recommend the removal of any fl ooring that is not attached
to the foundation ("fl oating fl oors") beneath the installation.
Requirements for protection of wooden
fl ooring beneath the fi replace
If you intend to place the product directly on a wooden fl oor,
you must use a bottom plate (item no. 10047361, optional
extra.
Requirements for protection of combustible
fl oors in front of the fi replace
The front plate must comply with national laws and regulations.
Contact your local building authorities regarding restrictions
and installation requirements.
For Norway: Minimum 300 mm in front of the door and width
at least the same as the door.
98
3.3 Walls
Distance to walls made of combustible material - see fi g. 2.
The fi replace may be used with a semi-insulated fl ue pipe
provided the distances between the fi replace and walls made
of combustible materials are as shown in Fig. 2.
NB: Ensure that furniture and other combustible materials are
not too close to the fi replace. Combustible materials must not
be placed within 1,000 mm of the fi replace opening.
3.4 Ceiling
If the ceiling above the fi replace is made of combustible
material, the minimum distance between the fi replace and
ceiling must be 700 mm, i.e. a minimum ceiling height of 2,400
mm.
4.0 Installation
NB: Before installing the fi replace, check it carefully for any
signs of damage.
NB: The product is heavy! Ask someone to help you when
positioning and installing it.
NB:
Read the installation and operating instructions for
Jøtul I 520 (cat. no. 10044945 and Jøtul S 71/S 72 (cat. no.
10047331) carefully before installing the fi replace!
Use the provided acrylic sealant for all joints.
Then fi t the steel chimney in accordance with the operating
instructions.
•
The insert must be connected to a chimney and fl ue
pipe approved for solid fuel fi replaces with a fl ue gas
temperature of 305°C.
•
The cross-section of the chimney must be at least that of
the fl ue pipe. Ø 150 mm cross section.
•
Several solid fuel products can be connected to the same
chimney system if the chimney cross-section is adequate.
See "2.0 Technical data".
For recommended chimney draught, see "2.0 Technical
Data". If the draught is too strong, a smoke damper can
be installed and used to reduce the
4.1 Prior to installation
The basic product comes in a package with concrete elements.
An insert (Jøtul I520) and a leg rack are also included.
NB: Check the product for signs of damage when you
unpack it.
NB: Check that the right insert is used for the selected
surround.
draught.