To remove the machine from the pallet, lift it as shown in Fig. 2.
The same lifting point must be used every time the site of machine installation is changed.
Remember to disconnect the machine from its pneumatic and electric power supply
before beginning such an operation.
PLACE OF INSTALLATION
WARNING
The place where the machine is to be installed must conform to applicable safety at
work regulations.
WARNING
The machine must not be installed in an open area.
Move the machine to the designated installation site, respecting the minimum distances
reported in Fig. 3.
- Relative humidity: 30% - 95% without condensation
- Temperature 0°C - +55°C
WARNING
The machine must not be operated in potentially explosive atmospheres.
ATTENTION
Place at a distance of at least 60 cm from any heat source (fig. 3).
Level the machine using the adjustable feet (7 fig.4).
Hook-up to the electric mains (see the section on Electrical and Pneumatic hook-up).
Various configurations can be created by adding sections to the base section.
To make a multi-section configuration add one additional section to the base section and
so on, up to a permitted maximum of 48 heads.
26
LIFTING/HANDLING
Work environment conditions
INSTALLATION
PW IW ~ 6" 8" 10" base section
PW IW ~ 6" 8" 10" additional section
PW IW 6" 8" 10" operator's manual