Device Storage; Connecting The Device; Connecting The Power - STAMOS S-WIGMA 180 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
The cable mustn't be wrapped around the body.
A welded object must be properly grounded.
Only equipment in good condition can be used.
Damaged device elements must be repaired or
replaced. Safety belts must be used when working
at height.
All fitting and safety elements must be stored in one
place.
From the moment of turning on the release, the
handle end must be kept away from the body.
The chassis ground must be mounted to the welded
element or as close to it as possible (e.g. to a work
table).
THE DEVICE CAN STILL BE UNDER VOLTAGE UPON
FEEDER DISCONNECTION.
The voltage in the input capacitor must be checked
upon turning off the device and disconnecting it
from the power source. One must make sure that the
voltage value is equal to zero. Otherwise, the device
elements must not be touched.
1.5. GASES AND FUMES
PLEASE NOTE! GAS MAY BE LETHAL OR DANGEROUS
TO HUMAN HEALTH!
Always stay clear of the gas exhaust.
Ensure proper ventilation of the work space and
avoid gas inhalation.
Chemical substances (lubricants, solvents) must be
removed from the surfaces of welded details as they
burn and emit toxic smokes under the influence of
temperature.
Welding galvanised details is permitted only when
efficient ventilation is provided with filtration and
access to fresh air. Zinc fumes are highly toxic, an
intoxication symptom is so-called metal fever.
2. TECHNICAL DATA
Product name
TIG Welder
Model
S-WIGMA 180
Voltage/frequency
230~/50
No-load voltage [V]
77 MMA
36 TIG
MMA welding current [A]
20-180
TIG welding current [A]
20-180
Duty cycle
30% (MMA, TIG)
Welding current [A] at 100%
98,6 (MMA, TIG)
duty cycle
ARC FORCE [MMA]
NO
HOT START [MMA]
YES
ANTI STICK [MMA]
YES
Insulation class
F
Efficiency (in nominal
80
conditions) [%]
Power coefficient [cos Φ]
0,7
Protection class IP
IP21S
MMA electrode diameter
1.6 – 4
[mm]
TIG electrode diameter [mm]
1.0 – 2.4
EN
3. OPERATION
3.1 GENERAL NOTES
The device must be applied according to its purpose,
with observance of OHS regulations and restrictions
resulting from data included in the rating plate (IP
level, operation cycle, supply voltage, etc.).
The machine must not be opened as it will cause
warranty loss and, in addition, exploding, unshielded
elements can cause serious injuries.
The manufacturer does not bear any responsibility
for technical changes in the device or material losses
caused by the introduction of the said changes.
In case of incorrect device operation, contact the
service centre.
Louvers must not be shielded – the welder must
be positioned at a 30 cm distance from the objects
surrounding it.
The welder must not be kept under your arm or near
your body.
The machine must not be installed in rooms with
aggressive environments, high dustiness and near
devices with high electromagnetic field emission.

3.2 DEVICE STORAGE

The machine must be protected against water and
moisture.
The welder must not be positioned on heated
surfaces.
The device must be stored in a dry and clean room.

3.3. CONNECTING THE DEVICE

3.3.1 Connecting the power

Connecting the device must be performed by
a qualified person. In addition, a person with the
required qualifications should check if the earthing
or electrical installation with protection system is in
line with the safety regulations and if they operate
correctly.
The device must be placed near the work station.
Connecting excessively long conduits to the machine
must be avoided.
One-phase welders should be connected to the
socket fitted with an earthing prong.
Welders powered from a 3-Phase network are
delivered without a plug, the plug must be obtained
independently and installation should be assigned to
a qualified person.
PLEASE NOTE! THE DEVICE MAY ONLY BE USED UPON
CONNECTION TO AN INSTALLMENT WITH A PROPERLY
FUNCTIONING FUSE.
4. S-WIGMA 180 MODEL OPERATING INSTRUCTIONS
Front view of the device Rear view of the device
6
6
4
1
2
3
8
Rev. 16.03.2018
Device description:
1.
Welding machine control panel
2.
„+" lead output
3.
„-" lead output
4.
Power cable
5.
Welding machine ON/OFF switch
6.
Carry handle
CONTROL PANEL VIEW
8
Control panel description
1.
Welding current display
2.
Welding current adjustment knob
3.
VRD indicator
Safety function – only for MMA welding: This
function allows to reduce the idling voltage to
a user-safe value when the device is ready for
welding. After commencing welding, the idling
voltage automatically grows to the nominal value,
and after finishing welding it drops back to the safe
value again.
4.
VRD gauge ON/OFF switch
5.
MMA method indicator
6.
Lift TIG method indicator
7.
Welding method selection button
8.
ERROR INDICATOR = The indicator lights in the
following two situations:
a. If the machine has malfunctioned and cannot be
operated.
b. If the cutting device has exceeded the standard
working time the protection mode is initiated and
the machine will stop functioning. This means that
the machine is now being cooled in order to be able
to restore temperature control again after the device
has overheated. Therefore, the machine is stopped.
During this process, the red warning light on the
front panel lights up. In this case it is not necessary
to remove the power plug from the socket. The
ventilation system may be left on in order to enhance
the cooling of the machine. When the red light goes
dark, this means that the temperature is now down
to the normal level and the unit can be put back into
operation.
4.1. CONNECTING LEADS
INSTRUCTIONS FOR CONNECTING LEADS:
MMA WELDING MODE:
5
1.
Use the selection button to select MMA welding
mode.
2.
Connect the return lead to the socket marked with
„+", and tighten the locking nut.
3.
Then connect the welding lead to the correct socket,
marked with the „–" sign and tighten the locking
nut. WARNING! The polarization of the leads may
be different! All polarisation information should be
shown on the packaging supplied by the electrode
manufacturer!
Rev. 16.03.2018
EN
4.
Now you can connect the power lead and turn the
power on, once the return lead is connected to the
welded element, you can start working.
5. TIG WELDING MODE:
1.
Use the selection button to select Lift TIG welding
mode.
2.
Connect the return lead to the socket marked with
„+", and tighten the locking nut.
3.
Then connect the TIG welding lead to the socket
marked with the „-" sign, connect the TIG welding
4
3
control lead and tighten the locking nut. Connect
1
the gas lead directly to the gas canister. Gas flow is
adjusted using the knob on the welding torch.
4.
Now you can connect the power lead and turn the
6
5
power on, once the return lead is connected to the
welded element, you can start working.
7
2
6. DISPOSING OF PACKAGING
The various items used for packaging (cardboard, plastic
straps, polyurethane foam) should be kept, so that the
device can be sent back to the service centre in the best
possible condition in case of any problems!
7. TRANSPORTATION AND STORAGE
Shaking, crashing and turning the device upside down
should be prevented when it is transported. Store it in
a properly ventilated surrounding with dry air and without
any corrosive gas.
8. CLEANING AND MAINTENANCE
Always unplug the device before cleaning it and
when the device is not in use.
Use cleaners without corrosive substances to clean
each surface.
Dry all parts well before the device is used again.
Store the unit in a dry, cool place, free from moisture
and direct exposure to sunlight.
9. REGULAR CONTROL OF THE DEVICE
Check regularly if the device does not present any damage.
If there is any damage, please stop using the device. Please
contact your customer service to solve the problem.
What to do in case of a problem?
Please contact your customer service and prepare the
following information:
Invoice number and serial number (the latter is to be
found on the technical plate on the device).
If relevant, take a picture of the damaged, broken or
defective part.
It will be easier for your customer service clerk to
determine the source of the problem if you give
a detailed and precise description of the matter.
The more detailed your information, the better the
customer service will be able to answer your problem
rapidly and efficiently!
CAUTION: Never open the device without the authorization
of your customer service. This can lead to a loss of warranty!
9

Publicité

Table des Matières
loading

Table des Matières