Start & Stop Procedure - Altrad Belle PCX 20/45 Manuel De L'opérateur

Plaques vibrante
Masquer les pouces Voir aussi pour PCX 20/45:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Improper maintenance can be hazardous. Read and Understand this section before you perform any
CAUTION
maintenance, service or repairs.
Honda GX160 Petrol Engine
1.
Open the fuel tap by moving the fuel ON/OFF lever fully to the right.
2.
If starting the engine from cold, set the choke ON by moving the choke lever fully
to the left. If restarting a warm engine, the choke is usually not required, however,
if the engine has cooled to a degree, partial choke may be required.
3.
Turn the engine ON/OFF switch clockwise to the 'I' position.
4.
Set the throttle to the idle position by moving the throttle lever fully to the right. Do
not start the engine on full throttle, as the compactor will vibrate as soon as the
engine starts.
5.
Taking a firm hold of the control handle with one hand, grasp the recoil starter
handle with the other. Pull the recoil starter until engine resistance is felt, then
let starter return.
6.
Taking care not to pull the starter's rope fully out, pull the starter handle briskly.
7.
Repeat until the engine fires.
8.
Once the engine fires gradually set the choke lever to the OFF position by moving it to the right.
9.
If the engine fails to fire after several attempts, follow the Troubleshooting Guide.
10. To stop the engine, set the throttle to idle and turn the engine ON/OFF switch anticlockwise to the '0' position.
11. Turn the fuel off.
Hatz 1B20 Diesel Engine (please refer to the engine manual for full details)
1.
Turn ON the fuel by moving the fuel ON/OFF lever fully to the right.
2.
Set the engine speed control to start.
3.
Taking a firm hold of the control handle with one hand, grasp the recoil starter handle with the other. Pull the handle until
engine resistance is felt, then let the starter return.
4.
Taking care not to pull the starter's rope fully out, pull the starter handle briskly with both hands.
5.
Repeat this procedure until the engine fires.
6.
If the engine fails to start after several attempts, consult the engine manual supplied with the compactor.
7.
To stop the engine, set the throttle control to idle, then press and hold the red stop button until the engine stops.