Putting into operation
Mode
Audible
Networked detector
Beeps once
Alarm
a second
Muting the detector –
Beeps twice every
Low battery
4 hours
Addressing
Addressing
successful

Replacing the battery

• If the battery is low, the wireless smoke detector beeps twice a minute (for up
to 30 days) to remind you to replace the battery.
• You must change this battery when you hear this signal.
• Even so, the wireless smoke detector remains functional in this condition.
• You must test the wireless smoke detector each time you change the battery.
• Carry out the test as detailed above to check if the functioning and the network
connection can still be guaranteed.
Note
To ensure a long service life and reliable operation, we recommend using
the following high-quality lithium batteries:
• Lithium: EVE CR9V-P

Cleaning and disposal

Visual
Notes
LED flashes twices
a second
Flashes twice every
Acoustically and
4 hours
visually in sync
Flashes once
a second
LED lights up for
5 seconds
– 34 –
The lifetime of the battery can be negatively affected by frequent alarms, dirt,
large variations in the temperature or similar environmental influences.
After changing the battery, the low battery warning may continue for a further
10 minutes, due to the nature of the network. Check the functionality after testing
the battery.
Alarms and error signals
When the alarm threshold is exceeded, a loud alarm sounds.
• The alarm continues sounding as long as there is smoke in the detection chamber.
• The alarm is only switched off when there is no more smoke in the detection
chamber.

Maintenance and inspection

A smoke detector must always be at least once a year in accordance with DIN 14676
are checked for functionality. A functional test can be triggered by short activation
of the test button with this smoke alarm (5 in Figure 1). The LED flashes quickly and
it includes a test alarm. To networked detectors also includes a test alarm.
Cleaning
• Dusty detectors must be cleaned. You can clean dust from the air vents of the
detector using a vacuum cleaner or compressed air. If necessary, you can remove
the dust with a brush.
• When changing the battery, carefully clean the detection chamber in the wireless
smoke detector with a vacuum cleaner to remove any dust or dirt.
• You can clean the surface using a cloth slightly dampened in soapy water.
Cleaning and disposal