Reset; Special Features; Shunt Regulation; Led Lightning - Depaepe SecurAccess Compact PMR Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SecurAccess Compact PMR – User Guide
Setting to modify
Changing the setting code
Your new access code :

3.14. Reset

Caution: this operation switches back the unit to all factory settings; it also erases all numbers stored
in memories. This operation can be done locally or remotely.
Local reset:
1. Open the unit and access to the PCB
2. Connect the unit to a powered telephone line.
3. Depress the RAZ button located on the PCB for at least 4 seconds (see page 5)
4. The unit starts emitting several "beep" tones during the reset
5. When the unit stops emitting "beep" tones, this means the reset is completed, the unit is back
to factory settings, including the programming code access (0000).
Remote reset:
1. Call the SecurAccess COMPACT PMR and enter the programming mode (see § 12.2.)
2. Select the reset setting choice code (91) and enter the programming access code and
terminate by entering *9.
3. The unit will start emitting "beep" tones during the reset
4. When the unit stops emitting "beep" tones, this means the reset is completed, the unit is back
to factory settings, including the programming code access (0000).
5. The unit will automatically hang up.

4. Special features

4.1. Shunt regulation

The unit is fitted with an automatic gain control system for plain old classical telephone lines.
In some cases, with very long lines or poorly powered lines (ATA, Operator modems, etc), the unit
may work poorly and it might be useful to shunt this regulation in order to recover more power and
ensure good working conditions. (See page 28).

4.2. Led lightning

The SecurAccess COMPACT PMR comes with 1 or 2 off-hook buttons and one label display which
can be lighted. Buttons and label display backlighting require the use of the external power supply
TRT3 24V DC/AC 1A (LPS) with double insulation (sold by Depaepe SAS) as well as the dedicated
switch activation.(see page 28/29).
Code
Setting choice
Factory settings are shown in grey
9 0
Enter the new 4 digits access code twice
note : 0000 = factory setting
40
Conf.
*9

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières