SecurAccess Compact PMR – User Guide
2 "beep" tones
Note: All correct entries are confirmed by a double "beep" tone Wrong entries are confirmed by a low long
"beep" tone and the unit will hang up.
3.3. Programming rules
1. Enter the programming mode (local or remote)
2. Choose the setting you wish to modify (See list of settings page XX) and enter its setting
access code.
Setting to modify
Settings
M1 storing for key 1
3. Enter the number to store (memory) or the setting change number.
Settings
M1 storing for key 1
4. Confirm by entering *9
Settings
M1 storing for key 1
5. Repeat the operation for other settings choices or terminate by hanging up or by
entering 99 for immediate hanging up.
Example N°1: In the local programming mode, storing number 18 in Memory key 1 (without chain
dialing)
Settings
M1 storing for key 1
Keep depressed M1 (front panel button) and * (small keypad inside)
Release M1
Release * button
Enter
2 "beep" tones
Enter
2 "beep" tones
Enter
Enter
2 "beep" tones
Confirming the entry
Setting access code
Code
Setting choice
2 0
Number (22 digits max.)
Number to store or parameter to change
Code
Setting choice
2 0
Number (22 digits max.)
Code
Setting choice
2 0
Number (22 digits max.)
Code
Setting choice
2 0
Number (22 digits max.)
2 "beep" tones: entering the programming mode
0000
4 digits access code (0000: factory settings)
Confirming entering the programming mode
20
Setting code access
Confirming the entry
18
Number to store (18 in this example)
*9
Confirming stored setting
Confirming the operation
* 9
* 9
Setting confirmation
* 9
Conf.
*9
35