Set the determined value on the temperature control.
By turning, you change the value in the „SET" line.
Briefly press the button „PRESET 2". This terminates
the setup menu and displays the current soldering
iron tip temperature.
If you press the button „PRESET 2" longer to finish, you switch back to the preset
temperature of „PRESET 2". In both cases, the calibration of the new soldering iron
is finished successfully. Turn the soldering station off when it is not in use.
You can cancel an accidentally started calibration process at any
time by turning the station off when the button „PRESET 2" was not
pressed yet. The preset values are preserved.
Maintenance and Cleaning
Apart from occasionally exchanging the soldering tip and external cleaning, the sol-
dering station is maintenance-free.
Exchanging the soldering tip
Turn the soldering station off and let the soldering iron cool down completely.
Loosen the metal cap nut on the shaft of the soldering iron. First pull off the metal
shaft and then the soldering tip.
Attach a new soldering tip and tighten the shaft carefully again.
If you have selected a different type of soldering tip, you have to cor-
rect the temperature of the soldering tip.
27