Installa On, Environmental Condi Ons, Rst Cleaning - Arneg Velden Twin self Manuel D'installation Et De Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Velden
English
How to
• the cabinets must be stored indoors, with a temperature ranging between-25°C and
+55°C and a humidity between 30% and 90%.
proceed
• before storing the cabinets, check that the packing is intact and that it does not di-
splay defect that may compromise preserva on of the cabinets.
What to
avoid

13. Installa on, environmental condi ons, rst cleaning

WARNING!
Before carrying out any opera on take all possible precau ons to prevent injury to the
operator, use the individual Personal Protec on Equipment provided
Installa on is reserved to technicians trained and authorized by the body speci ed in the
contract (manufacturer/dealer/distributor)
i
- It is the responsibility of the customer to provide the installa on area
- Changes to the setup described here must be authorized by ARNEG S.p.A.
The cabinet can be delivered packed as follows:
• with frame in wood xed to the base and nylon casing blocked by straps (standard) (Fig.9).
• with a cardboard casing (on request) (Fig.10).
• with wooden crate (upon request)(Fig.11)
The
• comply with the local standards in force
• comply with the environmental clima c class 9
installa on
• have a oor able to support the weight of the cabinet
area
• a switch with automa c protec on against short circuits, ground discharges and
dispersions between the electric power line and the machine;
should
• provide the space required for correct ven la on, use and maintenance
Ambient
For the cabinet to work properly, the room temperature and rela ve humidity must
not exceed the limits of a climate class 3 (+25°C; R.H. 60%) according to the standard
condi ons
EN-ISO 23953 - 2.
Cabinet
• make sure the packing is intact and that it does not display readily apparent damages;
• carefully perform the unpacking opera on in order not to damage the cabinet;
delivery
• check that cabinet components are intact
• should you no ce any damage immediately inform the manufacturer
Installa on
Step
procedure
1
2
3
4
5
6
7
8
36
UV rays. Permanent deforma on of plas c materials /damage of cabinet parts.
DO NOT store the cabinets in uncovered areas exposed to atmospheric agents
and to direct sunlight.
carefully examine the installa on area, elimina ng any danger to the operator;
remove the package only if the cabinet is placed in the opera on area
remove the fastening screws from the wooden frame (Fig.7)
remove the wooden frame
install and adjust the regula on feet at a maximum height of 25 mm (Fig.8)
adjust the horizontal posi on of the cabinet using a spirit level (Fig.6)
check that all feet are into contact with the oor
level the cabinet both in front and back
Install maximum 3 cabinets within the same power supply and cooling line
Should you need to move the cabinet, the la er must be levelled again. Incor-
rect levelling
Ac on
05060161 00 08-04-2015

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Velden 130 h125Velden 160 h125Velden 167 h150

Table des Matières