SELECTING TIP CARTRIDGES FOR THE TALON HANDPIECE

Metcal TATC tip cartridges come in a variety of tip geometries and in two standard
temperature ranges (500 Series and 600 Series). To select the correct tip:
1.
Use a tip that meets or overextends the length of the lead footprint.
2.
Pick the lowest temperature tip cartridge
that will accomplish the task. Start with a
500 Series cartridge and switch to a 600
Series only if you need more heat. The
temperature series is marked on the
shaft.

INSERTING AND REPLACING TIP CARTRIDGES

1.
Push the Power Switch "Off."
2.
THE TIP CARTRIDGE MAY BE HOT.
Removal Pad included with your system.
REMOVE CARTRIDGES!
3.
Push a new cartridge into the solder handle with the Cartridge Pad. Align the
flat side of the cartridge shaft with the opening in the handle. Push in the
cartridge until it seats.
4.
The cartridge is fully seated when the
insertion mark is flush with the front of the
handle. Do not push past this mark. Both
cartridges must be inserted properly.
5.
Push the Power Switch "On." The new tip
cartridge will heat up to temperature in less
than 20 seconds.
1. Clean, then tin tips well.
2. Ensure tips contact all leads on device, either the bevel or straight portion of the
tip can be used.
3. Squeeze tool. Wait for all leads to reflow.
4. Maintaining pressure, lift component.
TEMPERATURE SERIES
Pull out the cartridge using the black Cartridge
DO NOT USE METAL TOOLS (PLIERS, ETC) TO

TALON OPERATION

Copyright © 1998, Metcal, Inc. All Rights Reserved 7027-0400 Rev A