GB
E
NGLISH
Temperature Compensation:
If the analyzer detects that the temperature of the battery may make a
difference in the result, it will ask you to select if the battery temperature
is above or below freezing. It will resume the test after you make your
selection.
If the analyzer displays warning messages or other instructions after
you press ENTER to start the test, see "Error Messages."
BATTERY TEST RESULTS
At the end of an out-of-vehicle test, the MicroXL will display one of the
following decisions together with the state of charge (SOC) value and the
rated and actual CCA.
GOOD BATTERY
Return to service.
GOOD–RECHARGE
Fully charge the battery and return to service.
CHARGE AND RETEST
Fully charge the battery and retest. Failure to fully charge the battery
before retesting may cause false readings.
REPLACE BATTERY*
Replace the battery and retest to perform a complete charging system
analysis. A REPLACE BATTERY result may also mean a poor connec-
tion between the vehicle's cables and the battery. After disconnecting the
vehicle cables from the battery, retest the battery using the out-of-vehicle
test before replacing.)
BAD CELL–REPLACE*
Replace the battery and retest to perform a complete system analysis.
7
•
•