To realign, press MENU to cancel the print job. Verify alignment
between the analyzer and printer; then try to print the test results
again.
If the message PRINTING RESULTS appears on the screen, but no
data are printing, press MENU to cancel the print. Turn off the printer
and charge the printer battery for at least 15 minutes before attempt-
ing to print again. Align the analyzer and printer IR transmitters and
print again.
Make sure the printer is on. The printer shuts off after 2 minutes of
inactivity to conserve the battery. To turn the printer on, briefly press
the MODE button. The green STATUS light should turn on. Make
sure you are using the Midtronics printer provided with the MicroXL.
Other printers may not be compatible.
Direct sunlight interferes with infrared data transmission/receiving.
If the printer is not receiving data, remove the printer and MicroXL
from direct sunlight. If the printed characters are not clear or are
partially missing, recharge the battery and reprint.
Verify that the correct printer is selected in the analyzer. (See "B.
Printer Type," and "H. Config Printer" in the "Menu Options" section.)
Verify that a compatible communications protocol is selected in the
printer setup. (See "H. Config Printer" and the printer manual.)
If you are unable to print after ensuring the analyzer is functioning,
the printer is on, the battery is good, and the IR transmitter and
receiver are aligned, check the printer manual for further instructions
or call Midtronics at 800-776-1995 for assistance. (See "Patents,
Limited Warranty, Service" for more information.)