GB
ERROR MESSAGES
SURFACE CHARGE DETECTED
The battery will hold a surface charge if the engine has been running or
after the battery has been charged. The analyzer may prompt you to
remove the surface charge before it begins testing.
1. Follow the instructions on the display.
2. After detecting the removal of the surface charge, the tester will
resume testing.
SYSTEM NOISE / CHECK LOADS
The analyzer has detected computer or ignition noise and will attempt to
retest. Make sure all vehicle loads are off and the ignition is in the off
position. The analyzer will automatically retest when it no longer detects
system noise.
•
You may be testing too close to a noise source, i.e., a charger or
other high-current device. If so, move away and retest.
•
If no noise source is identified, fully charge the battery and retest.
If the message appears after recharging, replace the battery.
•
Disconnect the battery cables and retest.
UNSTABLE BATTERY
A battery that is very weak or that has just been charged may retain
enough electrical activity, which the analyzer has detected, to adversely
affect the test results. A fully charged battery should stabilize quickly,
after which the analyzer will automatically retest. Weak batteries should
be charged and retested.
NON 12-VOLT BATTERY DETECTED
You are attempting to test out-of-vehicle a non-12-volt battery or
batteries connected in series.
24-VOLT SYSTEM DETECTED
You are attempting to test in-vehicle both batteries in a 24-volt system.
Disconnect the batteries and test them individually. The analyzer will
bypass the battery test and the display will toggle between the warning
and PRESS ↵ FOR STARTER TEST.
E
NGLISH
18
•
•