GB
MENU OPTIONS
To select the following options, which are also available in QC (Quality
Control) mode, press and hold the MENU button.
The Menu options will be displayed three at a time. Use the UP/DOWN
ARROW buttons to scroll through the options and press ENTER to
select.
IMPORTANT: When you start a new test (outside of QC
mode) by connecting to the battery, the last test results in
memory will be lost.
1. Print Results (optional printer)
IMPORTANT: If you will be using the Midtronics printer for
the first time, charge the printer battery for 16 hours before
beginning your test session. Refer to the printer manual for
more information.
The MicroXL analyzer also has the ability to print the last test results (or
the entire data set in QC mode) by sending data from the analyzer's top-
mounted IR transmitter to the printer's IR receiver (below the MODE
button). To print, turn on the printer and align the IR transmitter with the
receiver. Select 1. PRINT RESULTS from the options Menu.
The results include battery test results and a test code (if available).
For the Micro500XL the results also include those for the starter system
and charging system tests. This option is also available in QC mode.
(For more information, see the sections "B. Printer Type," "H. Config
Printer" and "Printer Problems.")
2. View Results
The results available above are displayed on-screen. Press the UP
ARROW button to scroll though the results and return to the Menu
screen.
In QC mode you can view the complete data set in the QC memory.
Press the UP ARROW button to scroll from test to test. Press ENTER to
view the limits set for that test. Press ENTER again to return to the test
result.
E
NGLISH
14
•
•