WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect wall anti-tip brackets to wall behind range.
Connect range anti-tip brackets to underside of range.
Re-engage the anti-tip brackets, if the range is moved.
See the installation instructions for details.
Failure to follow these instructions can result in death
or serious burns to children and adults.
2. When the range is at the correct height, check that there is
adequate clearance between the range and wall to install the
anti-tip brackets. Before sliding range into its final position,
install anti-tip brackets.

Level Range

1. Place a rack in oven.
2. Place level on rack to check levelness of range, first side to
side, then front to back.
3. If the range is not level, pull range forward.
4. Manually adjust the leveling legs up or down. Turn leveling leg
sleeves to level range and to raise or lower range to the
desired countertop height.
NOTE: Range must be level for satisfactory baking
performance.
5. Continue installing your range using the following installation
instructions.

Install Wall Anti-Tip Brackets

Before moving range, slide range onto shipping base, cardboard
or hardboard.
1. Using a measuring tape, find and clearly mark the vertical
centerline on the wall of the range location. Use the
dimensions provided below to determine the position of the
wall anti-tip brackets on the rear wall of the cutout.
10
B
C
A. Centerline
B. 27½" (70.0 cm)
C. Determine distance from bottom of range
anti-tip brackets to floor and add ⁵⁄₈" (16.0 mm).
2. Measure distance from bottom of range anti-tip brackets to
floor, add ⁵⁄₈" (16.0 mm) to the distance and mark on the rear
wall of the cutout.
3. Measure out 13⁵⁄₈" (34.6 cm) right and left of the centerline (A)
made in Step 1 and mark the intersection to determine
placement of top of each bracket.
4. Securely attach the wall anti-tip brackets to the rear wall of
the cutout with drywall anchors and screws provided.
A
A. Wall anti-tip brackets
B. Drywall anchors
C. Anti-tip screws
5. Move range close enough to wall to allow for final electrical
connection. Remove shipping base, cardboard or hardboard
from under range.
A
B
C