Power Supply Cord
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use a new 40 amp power supply cord.
Plug into a grounded outlet.
Failure to follow these instructions can result in death,
fire, or electrical shock.
1. Disconnect power.
2. Remove the terminal block cover screws located on the back
of the range. Pull cover down and toward you to remove
cover.
A
B
A. Terminal block cover
B. Terminal block cover screws
C. Terminal block cover screw holes
D. Power cord insertion hole
E. Terminal block
3. Install strain relief.
Style 1: Power supply cord strain relief
■
Secure the strain relief onto the power supply cord by
tightening the screws with Phillips screwdriver.
NOTE: Allow for 6" minimum from power supply cord
wires to strain relief.
A. Power supply cord wires
B. Screw
C. UL listed strain relief
Electrical Connection - U.S.A. Only
C
C
D
E
A
B
C
Direct Wire
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper or 6 gauge aluminum wire.
Electrically ground range.
Failure to follow these instructions can result in death,
fire, or electrical shock.
■
Feed the power supply cord through the hole underneath
the terminal block on the bottom of the range. Allow
enough slack to easily attach the wiring to the terminal
block.
A
C
A. Terminal block
B. Rear of range
C. Power supply cord wires
D. Strain relief
E. Screws
■
Secure strain relief underneath the range by tightening
screws.
B
D
E
11