ELECTRICAL INFORMATION

GROUNDING INSTRUCTIONS

IN THE EVENT OF A MALFUNCTION OR BREAKDOWN, grounding provides the path of least
resistance for electric current, and reduces the risk of electric shock. This tool is equipped with a
POLARIZED plug. The plug MUST be plugged into a matching grounded extension cord in
accordance with All local codes and ordinances.
DO NOT MODIFY THE PLUG PROVIDED. If it will not fit the properly grounded extension cord,
have the proper outlet installed by a qualified electrician.
CAUTION
ALWAYS MAKE SURE THAT YOUR OUTLET IS PROPERLY GROUNDED.
IF UNCERTAIN, HAVE IT CHECKED BY A CERTIFIED ELECTRICIAN.
WARNING
THIS GRASS TRIMMER IS FOR OUTDOOR USE ONLY. DO NOT EXPOSE
TO RAIN OR USE IN DAMP LOCATIONS.
GUIDELINES FOR USING EXTENSION CORDS
USE THE PROPER EXTENSION CORD. Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy enough to carry the current your product
will draw. An undersized cord will cause overheating. The table below shows the correct size to use
depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge.
The smaller the gauge number, the heavier the cord.
Ampere Rating
More Than
Not More Than
0
6
10
12
Minimum Gauge for Extension Cords (AWG)
(when using 120 V only)
25' (7.6 m)
6
10
12
16
Total Length of Cord in Feet (meters)
50' (15 m)
18
16
18
16
16
16
14
12
6
100' (30.4 m)
150' (45.7 m)
16
14
14
Not Recommended
14
12
12