______________________________________________________________________
1.6
Safe distances
The following distances must be respected as safety margins from flammable objects
and bearing walls made of reinforced concrete and partition walls made from flammable
materials or covered in flammable materials:
Beneath the hob plate (from the top of the stove to the floor)
Above the hob plate (radiation area of the hob plate)
*The silicon dividers which are supplied must be fitted to the side panel to ensure
this.
Any flammable items attached above the stove must be kept at a suitable distance. The
minimum distance is 800 mm.
Floor in front of the stove
Floors made of flammable substances, such as e.g. carpets, parquet, laminate, plastics
or cork, must be replaced or covered by a non-flammable substance e.g. ceramic,
stone, glass or a steel floor-plate for a distance of 500 mm forwards and 300 mm
sideways.
The connection piece must not pass between flammable building materials or furniture.
If connected at the side, the safety gap required by the manufacturer between it and any
flammable materials must be respected.
B
______________________________________________________________________
A ≥ 800 mm
A ≥ 800 mm
C
B ≥ 3 mm*
B ≥ 300 mm
A
34
C ≥ 200 mm
C ≥ 200 mm
B