OPERATION
POWER ON/OFF
Press
for 1s to power-on scale. Scale perform initialization and power-on test,
"0.0.0.0.0" shows twice, then capacity 3000 |5000 shows, battery life percen-
tage bat90 shows, weight detection ----- shows and then auto zero.
For information about Auto-Zero, refer to Scale Configuration in Technical Manual.
Press
or
for 1s to power-off scale. Battery life percentage bat90 shows, off
message |off| shows, and then cut off power.
ZERO
Press
or
to zero. ZERO light on.
If load is in motion, or tared, or out of Manual-Zero Range, |err| shows.
For information about Manual-Zero Range, refer to Scale Configuration in techni-
cal manual.
EN
TARE IN/OUT
In gross mode, press
or
If load is in motion, or negative, or out of Tare Range, |err| shows. Tare will re-
duce the apparent overload range of scale. For example, if a 5000*2kg scale has
a 1000kg container as its tare, the scale will overload at a new weight of 4018kg
(5000 – 1000 + additional 9 divisions).
In net mode, press
or
to tare out. TARE light off.
LOCK/UNLOCK
Press
or
to lock screen. HOLD light on.
Press
or
to unlock screen. HOLD light off.
ACUUMULATE
Press
to accumulate current weight.
|acc| shows, indicating weight is accumulated. Scale uses displayed weight, so
gross or net weight is added into the same accumulator.
If load is in motion, or negative, or does not return to zero before, |err| shows.
to tare in. TARE light on.
27
VIEW
Press
to enter View mode.
Display flashes accumulated weight.
Press
or
to view high 5-digit or low 5-digit.
Press
or
to exit View mode.
DELETE LAST WEIGHT
Press
to delete last accumulated weight.
|del| shows, indicating last accumulated weight is deleted. Delete function only
deletes the last weight. If last accumulated weight has been deleted, |err| shows.
CLEAR ALL WEIGHT
Press
first and then press
to clear all accumulated weight.
|clr| shows, indicating all weight is cleared.
UNIT SWITCH
Press
to switch unit in between kg, lb, and User Unit.
When unit is kg, kg LED light on. When unit is lb, lb LED light on. When unit is
User unit, kg and lb LED all light off. For more information about User Unit, refer
to Scale Configuration in Technical Manual.

USER SET UP

The user setup enables you to fix several functions of the scale so that it better
fits your expectations by using it. The different parameter can be determined one
after another.
Entering the user setup
Press
first and then press
or
AUTO-OFF TIMING
Press
or
to enter Auto-Off Timing. off?? shows.
Press
or
and
to change timing value.
Auto-Off Timing can be set to: 0(disabled), 5(5min), 10(10min), 15(15min),
30(30min), 60(60min). It is set on 15 min by default.
Auto-Off function maximizes scale's battery life against people's carelessness not
to power off scale when it's not working. Auto-Off starts countdown timer when
there's no action or load is stable. Any key pressing or motion in load restarts
countdown timer.
to enter user setup menu. setup shows.
28