GAS CONNECTION

All gas connections must be made by a
qualifi ed, registered gas engineer.
Before proceeding with the installation, check
that the local supply (gas pressure and type) is
compatible with the default appliance values.
Take the necessary steps to ensure correct air
circulation.
Information on the gas supply can be found on
the appliance data plate.
This appliance is not connected to a
combustion residue extraction device. Ensure
that the appliance is connected in accordance
with applicable installation regulations. Pay
attention to ventilation requirements.
After all work, check that the tightening torque
of the gas connections is between 15 Nm and
20 Nm.
Where required, use a pressure regulator
meeting the appropriate standards and
regulations.
On completing installation, check for any leaks
with a soapy solution, never with a fl ame.
When connecting up the gas hose, this must
not exceed the maximum
by regulations
.
Pipes and hoses must not come into contact
with moving parts and must not be crushed or
pinched.

GENERAL INFORMATION

Connection to the mains gas supply can be made
using rigid copper tube, continuous wall or fl exible
steel hose, depending on the requirements of
applicable local gas regulations.
The appliance is tested in accordance with the
information given on the data plate. For use with
other types of gas, see the "
chapter. The incoming gas connection is
externally threaded ½" BSPP (ISO 228-1)
length provided for
GAS
CONVERSION"
.
CONNECTING THE APPLIANCE TO THE GAS
SUPPLY
Before connecting the appliance to the gas
supply, check that the data on the product
identifi cation label is compatible with the gas
supply specifi cations.
When the gas is supplied from the mains, the
appliance must be connected to the gas supply
with rigid copper tube or via a steel hose, in
accordance with applicable legislation.
When the gas is supplied from a cylinder, via a
compliant pressure regulator with continuous-
wall stainless-steel hose, it is advisable to install
a special after-market adapter on the hose to
facilitate connection with the hose barb of the
pressure regulator installed on the cylinder.
Do not tilt or overturn the cylinder.
Use high quality LPG; if you have any doubts, use
an LPG fi lter.
The hose must not pass through compartments
which may be fi lled, and must not come into
contact with moving components such as drawers.
On completing installation, check for any leaks
with a soapy solution, never with a fl ame.
WARNING: Remember that the appliance's gas
inlet is a male 1/2" BSPP fi tting to ISO 228-1.
/ Installation
EN
11