/ Installation
GAS CONVERSION
GAS CONVERSION
Step 2: Burner minimum adjustment
The oven thermostat has a screw for adjustment
of the minimum burn position. When the gas
supply type is changed, regulation of the
minimum position is required
as follows:
EN
1. Pull the oven out from its niche by at least 5
cm (only ovens with metal control panel).
2. Slacken off the screws holding the control
panel and remove it (only ovens with metal
control panel).
3. Light the oven burner and run at maximum
temperature for 10-15 minutes with the door
closed.
4. Turn the knob to the minimum temperature
position.
5. Remove the knob, introduce a fl at-head
screwdriver and turn the screw to adjust the
minimum position.
6. When using liquefi ed gas, the screw will need
to be turned all the way to the right.
GAS CONVERSION TABLE
Burner
Gas type
Town gas G110
Natural gas G20
Oven
Butane G30
Propane G31
Town gas G110
Natural gas G20
Grill
Butane G30
Propane G31
14
Pressure
N o z z l e
diameter
mbar
1/100 mm g/h
8
220
20
113
30
75
37
75
8
175
20
95
30
64
37
64
Nominal fl ow rate
l/h
kW
kcal/h kW
-
567
2.5
2150
-
238
2.5
2150
181
-
2.5
2150
178
-
2.5
2150
-
408
1.8
1548
-
171
1.8
1548
130
-
1.8
1548
128
-
1.8
1548
Flow rate
B y p a s s
Reduced
diameter
kcal/h 1/100 mm
0.8
688
41 reg
0.8
688
41 reg
0.8
688
41
0.8
688
41
-
-
-
-
-
-
-
-
-
-
-
-