BEFORE USING

LOCATION AND INSTALLATION

 The patio heater is intended for outdoor* use.
 Make sure, at all times, that there is sufficient air ventilation.
 Find a location a good distance away from flammable
materials: keep a free space of at least 75 cm on top and
100 cm at the sides.
 Place the patio heater on a sturdy, stable, flat and horizontal
surface.
 Never use it in areas where this is a risk of explosion, such
as rooms where gas or other flammable substances are
stored.

GAS REQUIREMENTS

 The system must be installed in accordance with the instructions and the legal regulations.
 Use in enclosed spaces is dangerous and is forbidden.
 Only for use outdoors and in spaces where there is adequate ventilation. A well ventilated
room is one where 25% of the wall surface-area is open. The surface of the walls is the sum
of the total surface.
 System category A
 Only use propane or butane gas 3B/P(30)..
 The maximum entry pressure on the gas regulator may not exceed 10 bar.
 A minimum supply pressure of 30 mbar is required.
 The gas regulator and hose must fulfil legal requirements.
 The installation must conform to legal guidelines for storage and use of liquid petroleum
gases.
 A dented, rusted or damaged bottle of gas could be dangerous and must be checked by the
gas supplier. Never use a gas bottle that has a damaged valve.
 Never connect a gas tank that does not fulfil regulations to the patio heater!

CHECKING FOR GAS LEAKS

The connections on the patio heater are checked for leaks in the factory before shipping. In
order to make sure damage has not occurred during transport or as a result of high pressure,
another complete leak test must be carried out during installation.
 Carry out the check with a full gas bottle.
 Set the control button to OFF.
 Make a soapy solution using one part liquid soap to one part water.
- 26 -
1
Tighten both gas connectors with spanner
no. 17
2
Check all connections for gas leaks with
soapy water

Publicité