For your safety
1 For your safety
1.1 Authorised personnel
All operations described in this operating instru-
ctions manual must be carried out only by trained
specialist personnel authorised by the plant opera-
tor.
During work on and with the device the required
personal protective equipment must always be worn.
1.2 Appropriate use
The LFV 230 is a sensor for point level detection.
You can nd detailed information on the application
range of LFV 230 in chapter "Product description".
1.3 Warning about incorrect use
Inappropriate or incorrect use of the instrument can
give rise to application-specic hazards, e.g. vessel
overll or damage to system components through
incorrect mounting or adjustment.
1.4 General safety instructions
This is a high-tech instrument requiring the strict
observance of standard regulations and guidelines.
The user must take note of the safety instructions in
this operating instructions manual, the country-
specic installation standards as well as all prevai-
ling safety regulations and accident prevention rules.
The instrument must only be operated in a
technically awless and reliable condition. The
operator is responsible for trouble-free operation of
the instrument.
During the entire duration of use, the user is obliged
to determine the compliance of the necessary
occupational safety measures with the current valid
rules and regulations and also take note of new
regulations.
1.5 CE conformity
The protection goals of the EMC Directive 2004/
108/EC (EMC) and the Low Voltage Directive 2006/
95/EC (LVD) are fullled.
14
Conformity has been judged according to the
following standards:
EMC: EN 61326-1
(electrical instruments for control technology and
laboratory use - EMC requirements)
l
l
LVD: EN 61010-1
(safety regulations for electrical measurement,
control and laboratory instruments - part 1: General
requirements)
2 Product description
2.1 Configuration
Scope of delivery
The scope of delivery encompasses:
l
l
l
2.2 Principle of operation
Application area
LFV 230 is a point level sensor with tuning fork for
point level detection.
It is designed for use in liquids in the food and
pharmaceutical industries.
Function monitoring
The electronics module of LFV 230 continuously
monitors via frequency evaluation the following
criteria:
l
l
l
If a malfunction is detected or in case of power
failure, the electronics takes on a dened switching
condition, i.e. the output is open (safe condition).
Functional principle
The tuning fork is piezoelectrically energised and
vibrates at its mechanical resonance frequency of
approx. 1100 Hz. When the tuning fork is submer-
Subject to change without notice
Emission: Class B
Susceptibility: Industrial areas
LFV 230 point level switch
Test magnet
Documentation
this operating instructions manual
-
WRA certicate (optional)
-
Strong corrosion or damage on the tuning fork
Loss of vibration
Line break to the piezo drive
LFV 230