Dometic RMV5301 Notice D'utilisation page 32

Masquer les pouces Voir aussi pour RMV5301:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Troubleshooting
Displays for faults and beeps
Faults are indicated by the flashing of individual buttons on the control panel, a beep
or a combination of both.
Display
With AC operation:
and
flashing,
a beep is emitted for
20 seconds
With DC operation:
and
flashing,
a beep is emitted for
20 seconds
and
flashing,
a beep is emitted for
20 seconds
flashes
With AC operation:
and
flashing, a beep
is emitted for 20 seconds
With DC operation:
and
flashing, a beep
is emitted for 20 seconds
In gas and automatic mode:
and
flashing, a beep
is emitted for 20 seconds
Beep is emitted for
15 seconds at intervals of
two minutes
32
Problem
The AC heater element or
the cooling unit is
defective.
The DC heater element or
the cooling unit is
defective.
The burner or the cooling
unit is defective.
The temperature sensor
has no contact or is
defective.
The power supply is not
available or insufficient.
The power supply is not
available or insufficient.
The burner flame is not
ignited.
The interior light is
switched on.
RMV5301, RMV5305
Suggested remedy
Contact the authorised customer
service.
Check the AC power cable,
the power supply and the fuse.
Check the DC power cable,
the vehicle battery and the fuse.
Check the D+ signal on the
vehicle.
Check the gas supply (gas
cylinder, gas valve).
Press the
button once the
fault is rectified.
Check whether the refrigerator
door is properly closed.
Close the refrigerator door.