Electric Connections - Quick PAJ 1T MSC Manuel D'installation Et D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

INSTALLATION
EN

ELECTRIC CONNECTIONS

The command meets standard EMC (electromagnetic compatibility). In any case correct installation is fundamental in or-
der not to affect its performance or interfere with operation of instruments found near it.
For this reason, the PAJ 1T MSC cables must be at least:
• 1 m away from cables that transmit radio signals (except for SSB radio transmitters).
• 2 m away from cables for SSB radio transmitter signals.
The connection between PAJ 1T MSC and MSC is performed via 24AWG Ethernet patch cable.
One RJ45 plug of the connecting cable must be inserted into the RJ45 socket of the command, while the other into the
CTRL1 socket (or alternatively CTRL2) of the MSC device.
Up to two PAJ 1T MSC commands can be simultaneously connected to the same MSC.
CTRL1
CTRL2
PAJ 1T MSC
PAJ 1T MSC
ETHERNET PATCH CABLE
ETHERNET PATCH CABLE
RJ45
RJ45
MOTOR I/O
CTRL1
CTRL2
STATUS
CAN
MSC
M
THE WIRING DIAGRAM
For the electrical connection of the MSC system, refer to the MSC User Manual.
14
PAJ 1T MSC REV001A

Publicité

Table des Matières
loading

Table des Matières