2.3 Technical specifications

Power specifications
Typ
Power
P1
S A N I C U B I C
®
[kW]
GR
SE71.1 S
2,2
SE71.1 T
2,1
SE71.2 T
2,1
SE71.3 T
3,9
SE71.4 T
3,9
Maximum medium temperature: 55°C
Materials
Container
Pump housing
Rotor
Seal supports
Cutting flange

2.4 Area of usage

The effluent lifting units of the SANICUBIC
and conveying) of domestic and industrial effluent that develops underneath the canal backflow level.
The model with cutting unit pumps enables pumping off over greater conveying heights and pressure
main lengths. The pressure main may be laid at a dimension of DN 50.
Double systems are used wherever an interruption of the effluent disposal system is not permitted to
occur, in terms of DIN 1986.

2.5 Scope of delivery

The effluent lifting units of the SANICUBIC
• assembled cutting unit pump(s) of the SANIPUMP
• connection for emergency evacuation
• pneumatic control and switch boxes
• inflow bend DN 100
• flexible connection for ventilation of the collection chamber
• pressure decrease bend DN 50
• back-kick flap(s) DN 50
• forked pipe DN 50/50/50 (only for double system)

3. TRANSPORT AND INTERIM STORAGE

3.1 Transport

The effluent lifting units of the SANICUBIC
Moreover, they are to be transported in a horizontal position.

3.2 Interim storage/conservation

The machine can be kept in interim storage and conserved in a cool, dark, dry and frost-free site. The
systems should stand in horizontal position.
Power
Voltage
P2
U
reception
[kW]
[V]
1,7
230
1,7
400
1,7
400
3,2
400
3,2
400
PE HD
GG 20
GG 20
GG 20
Stainless steel
 GR production series are used for the disposal (collection
®
GR production series are delivered with:
®
  GR production series may not be thrown or dropped.
®
Power
Rotational
speed
I
[A]
[n
]
-1
N
10,5
2 800
3,7
2 800
3,7
2 800
6,5
2 800
6,5
2 800
Cutting blade
Motor shaft
Seals
Axial face seals
ZFS 71 production series
®
Flage
Inlet
Inlet
Pump
height
h [mm]
DN 50
single unit:
DN 100
DN 50
DN 50/100
DN 50
double unit:
DN 50
DN 100
DN 50
DN 100/150
Stainless steel
Stainless steel
NBR, FPM
SiC (silicon carbide)
250
576
250
586
7