Technical Data - SFA SANISUB ZPK 30 Notice De Service / Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
UK
FR
1. SAFETY
WARNING, This device can be
used by children who are at least
8 years old and by people with
reduced
physical,
mental capacities or those without
knowledge or experience, if they are
properly supervised or if they have
been given instructions on safely
using the device and the associated
risks
have
Children should not play with the
device. Children should not clean or
perform maintenance on the device
without supervision.
ELECTRICAL CONNECTIONS : The
device's power supply must be
connected to ground (class I) and
protected by a high sensitivity
differential circuit breaker (30 mA).
The connection must be used
exclusively to provide the power to the
product.
If the power cord is damaged, to
prevent possible danger, it must
be replaced by the manufacturer,
customer service team or a similarly
qualified individual.
Disconnect
supply before carrying out
work on the unit!
The installation and operation of
your pump must comply with local
standards.
2. AREA OF USAGE
SANISUB ZPK is suitable for conveying slightly
contaminated water with suspended solids (no
rocks) from private households or commercial use.
The size of suspended solids must not exceed
10 mm (SANISUB ZPK 30), or 30 mm (SANISUB
ZPK 40). The pump must not be used to convey
waste waters containing substances which attack
or damage the pump's materials.
The pump is not approved for conveying waste
waters containing faeces.
SANISUB S ZPK series pumps are suitable for salt
water (sea water, water from water softeners, etc.)
3. LIST OF PARTS PROVIDED
See figure 2.
sensory
been
understood.
the
electrical

4. TECHNICAL DATA

Power rating P1
Voltage
or
Frequency
Power input
Speed rotation
Max. discharge flow Q
Max. discharge height
H
max
Max. liquid temperature
Discharge connection
Diameter
Total height
Supply cable
Weight with cable
Max. submersion depth
Minimum liquid level
Max. particle size
Float switch
Length of the float cable
Materials
Pump housing
Motor housing
Motor shaft
Bottom filter
Motor casing
Impeller
Float switch
Screws
Mechanical seal
This piece of equipment complies with the
directives and European standards on electric
safety and electromagnetic compatibility.
4
ZPK 30
ZPK 40
300 W
850 W
230 V
50 Hz
1.3 A
3.7 A
2800 rpm
7.0 m³/h
10.0 m³/h
max
7.5 m
10 m
40 °C continuously
70°C short-term
G 1¼"
150 mm
270 mm
345 mm
10 m
4.4 kg
6.6 kg
5 m
120 mm
200 mm
10 mm
30 mm
Yes
400 mm
Polypropylene (PP)
Polypropylene (PP)
Stainless Steel
Polyethylene (PE)
Stainless Steel
PA 6
Polypropylene (PP)
Stainless Steel
Carbon/Ceramics

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Sanisub s zpk 30Sanisub zpk 40Sanisub s zpk 40

Table des Matières